(a) Nitrogen oxides (NO X ) monitors. In accordance with the compliance schedule in §117.9320 of this title (relating to Compliance Schedule for Cement Kilns), the owner or operator shall install, calibrate, maintain, and operate a continuous emissions monitoring system (CEMS) or predictive emissions monitoring system (PEMS) to monitor kiln exhaust NO X .
(b) CEMS requirements. The owner or operator of any CEMS used to meet the monitoring requirement of subsection (a) of this section shall comply with the following.
(1) The CEMS must meet the requirements of 40 Code of Federal Regulations Part 60 as follows:
(2) One CEMS may be shared among kilns, provided:
(3) The CEMS is subject to the approval of the executive director.
(c) PEMS requirements. The owner or operator of any PEMS used to meet the monitoring requirement of subsection (a) of this section shall comply with the following.
(1) The PEMS must predict the NO X emissions in the units of the applicable emission limitations of this division (relating to Cement Kilns).
(2) The PEMS must meet the requirements of §117.8100(b) of this title (relating to Emission Monitoring System Requirements for Industrial, Commercial, and Institutional Sources).
Source Note: The provisions of this §117.3140 adopted to be effective June 14, 2007, 32 TexReg 3206